13.09.2026

3:1 or 2:1 wire binding: hole pitch and complete notebook thickness

3:1 or 2:1 wire binding: hole pitch and complete notebook thickness

Holes first. Thickness second.

First match 3:1 or 2:1 wire pitch to the punched holes. Then choose the wire diameter for the complete block thickness, including covers. An A4 label and a larger diameter do not change the distance between holes.

This article covers double-loop metal wire binding. Plastic combs, single spirals and disc systems have different constructions; their specifications cannot be transferred to this choice.

Three different dimensions on one label

The label “A4, 3:1, 34 loops, 9.5 mm” describes several properties at once. Each answers a different question.

Length / loop count

What spine length does the wire cover? Check the loop count against the edge you intend to bind.

3:1 or 2:1 pitch

Where do loops repeat along the spine? This spacing must match the centres of the punched holes.

Diameter, mm

How large is the closed loop across the spine? Choose it to accommodate the thickness of all the block materials.

The two A4 wires discussed below are listed with 34 loops for 3:1 and 23 loops for 2:1. These are specifications of those precut lengths. Check the loop count separately for a different spine length. Dividing the 297 mm height of A4 by 34 loops does not give the pitch: the outermost centres are inset from the paper edges, and 34 centres have only 33 intervals between them.

Identify pitch from the hole centres

One inch is 25.4 mm. A 3:1 pitch means three centre-to-centre intervals per inch: 25.4 ÷ 3 ≈ 8.47 mm. A 2:1 pitch means two: 25.4 ÷ 2 = 12.70 mm. More intervals over the same length means more closely spaced holes.

On a punched sheet, locate the centres of eleven consecutive holes. Measure from the first centre to the eleventh: that covers ten intervals. Align the ruler with the centres, not the outside edges of the holes.

Top view · spine shown horizontally · along the row of holes →

3:1 · one interval ≈ 8.47 mm

111

10 × 25.4 ÷ 3 ≈ 84.67 mm

11 centres · 10 intervals

2:1 · one interval = 12.70 mm

111

10 × 25.4 ÷ 2 = 127 mm

11 centres · 10 intervals

Both rows use the same relative scale: the 3:1 span is two thirds of the 2:1 span. Hole outlines are schematic; the tick inside marks the centre. This illustrates nominal pitch. It is not an on-screen ruler or a production-tolerance check.

↕ Loop diameter

Diameter is measured in another plane

End view of the spine: looking along the row of loops.

The circle schematically shows a closed loop viewed end-on. Increasing its diameter makes more room for the block but does not move the loops along the spine. The pitch in the diagram above is measured in a different direction.

If the result is close to one of these nominal values, cross-check it against the wire label and the punch specifications. For a new block, punch a sample of an allowed material and place the corresponding wire against it: the loops must line up with the holes along the entire length. An unclear result calls for checking the centres and binding system before buying.

Two A4 wires, two different hole patterns

These two specific MyPrint catalogue examples help you read the markings. They do not determine the diameter for your block.

For holes punched at 3:1 pitch

MyPrint 3:1 wire, 34 loops, 9.5 mm

A4 · item 12765 · black

Catalogue guide: up to approximately 70 sheets of 80 gsm paper.

For holes punched at 2:1 pitch

MyPrint 2:1 wire, 23 loops, 15.9 mm

A4 · item 12778 · white

Catalogue guide: up to approximately 135 sheets of 80 gsm paper.

A 15.9 mm wire with 2:1 pitch cannot replace a 9.5 mm wire with 3:1 pitch in existing holes. If you align the first centre, the following positions drift apart: 8.47 mm versus 12.70 mm. Occasional matches further along do not make the entire row compatible. Do not stretch the wire to force the pitch to fit.

The sheet-count guides are tied to 80 gsm paper. They do not promise the same capacity with thick covers, photo paper or mixed materials. Check the specific binder's capabilities in its own specifications: a related-machine list on a product page does not establish support for both pitches.

120 pages can produce two different blocks

A page is one side of a sheet. In our hypothetical example, 120 double-sided printed pages use 60 paper sheets. There are no inserts or blank sheets. We add two covers, each 0.30 mm thick.

The paper-sheet thicknesses of 0.10 mm and 0.20 mm are assumptions for this comparison. They do not mean that all 80 gsm paper is 0.10 mm thick.

Side view · paper lies flat · thickness is measured vertically ↕

Thinner paper sheet

60 sheets × 0.10 mm

6.60 mm

60 × 0.10 + 2 × 0.30 = 6.60 mm

Thicker paper sheet

60 sheets × 0.20 mm

12.60 mm

60 × 0.20 + 2 × 0.30 = 12.60 mm

Cover: 0.30 mm
Paper block

Layer heights share one scale: every cover is identical, while the paper section on the right is twice as thick. On a narrow screen, the thicker block appears below. These are hypothetical cross-sections, not measurements of finished products.

The page count stayed the same, but the total thickness rose from 6.60 to 12.60 mm. Grams per square metre describe paper mass per area, not thickness. Even a correct sheet count therefore cannot replace measuring the whole actual block.

Assemble every sheet, the actual covers and any intended inserts in their finished order. Align the stack and measure its full thickness without squeezing it hard, or use the binder's designated thickness guide. This complete set becomes your sample for selecting wire.

Use block thickness to select wire diameter

Compare the measured thickness with the sizing guide for the particular wire or binder, keeping the required pitch and staying within the closer's supported range. The example's 6.60 mm does not automatically call for 9.5 mm wire. There is no universal “add 2 mm” rule: your particular materials need room to turn freely.

Once you know the pitch and full thickness, browse MyPrint binding supplies. Choose the metal-wire type, then check pitch, length and diameter. If a sizing chart is unavailable, give a consultant the pitch, spine length and measured full thickness, along with the cover materials. “A4” or a page count alone cannot replace these details.

One punching batch is not the whole block

Punching capacity refers to the number of sheets per operation and the stated material. Binding capacity refers to the entire assembled document. These are separate limits.

  1. Punch. Divide the paper into batches within your particular punch's limits. A paper rating does not authorize punching binding board.
  2. Assemble. After punching, restore the sheet order and add appropriately prepared covers. The whole block goes into the wire.
  3. Close. Close the wire using your binder's procedure. Check the entire sample including covers, not just one thin batch.

Before the run, make one complete sample

  • Match the loops to the full row of holes, with no progressive misalignment or forced stretching of the wire.
  • Check wire length and loop closure along the spine against your binder's setting.
  • Turn the pages and both covers through the whole block: they should move freely without pinching or catching on the wire. If the pitch matches but turning is tight, check closure and diameter selection for the complete block before the run.

For an order, prepare a short specification: double-loop metal wire; pitch; length / loop count; full thickness including covers; binder model. Selection starts with the actual holes and materials and ends with checking the finished notebook.